Product Description
Introduction
Plate type shaker is a kind of laboratory pretreatment equipment which applies to solid waste extraction toxicity identification by platform rotary shaking. It’s the stipulated instrument of Standard (HJ/299-2007)& (HJ/300-2007), which is issued by Ministry of Environmental Protection of the People’s Republic of China. Widely applied in the related industry of solid waste toxicity identification, research & treatment such as environmental & solid waste dispose.
Plate type Shaker: Solid waste extraction toxicity instrument (TCLP) Rotation Method:
-- Stipulated instrument of Chinese National Standard GB50085.3-2007 (Apply HJ/T299-2007)
-- Stipulated instrument of Chinese National Standard GB16889-2008 (Apply HJ/T300-2007)
-- Selected instrument of America EPA 1311 method.
While the waste solid which contained with toxic substance encountering with water, it will leaching and the harmful substance will be transformed, which will cause pollution to environment. The leaching test is the outdoor or experimental simulation of this natural progress. While the extracted harmful substance exceed the stipulated standards, then we identify the waste solid with leaching toxicity. The solid waste leaching toxicity identification method is the standard of dangerous waste identification. And it’s also the key technical progress of solid waste management & dispose.
Characteristic
Type: 4/6/8/10/12 bottles
Material: Overall aluminum structure
Safety Device: With electricity leakage protection device & overload protection device
Adapted container: 2L PE bottle, Glass bottle, Teflon bottle & pollutant extraction container.
Alternative Accessories: Extraction container, high pressure filter system, extraction liquor collector, extraction agent, micro hole filter screen, etc.
This machine owns large load-bearing capacity, stable rotation speed, long time continuous & stable working with low noise.
Configuration for Non-volatile substance extraction:
1. Plate Type Shaker
2. Positive/negative pressure filter system
3. Micro hole filter screen: diameter 142mm, bore diameter 0.8μm
4. Extraction container: 2L jar with screw cap & inner cap to extract the non-volatile & half volatile substance. Extract bottle should be made of inert material which won’t extract or absorb substance in sample.While analysis inorganic material, apply glass bottle or PE bottle; While analysis organic material, apply glass bottle or PTFE bottle.
Configuration For Volatile substance extraction:
1. Plate Type Shaker
2. Zero Head Space Extractor
The specialized container for volatile substance extraction in sample
Material: 316 stainless steel
Dimension: capacity 550ml, diameter 90mm
Temperature tolerance: 4℃ low temperature durable
Voltage tolerance: 50psi above
Pressure gauge: 0-60psi
3. Extraction liquor collector
4. Extraction agent conveyor
5. Micro hole filter screen: Diameter 90mm, hole diameter 0.8μm
Other Model Types for Choose
Model |
Bottle |
Bottle Size |
Rotate Speed |
Power Supply |
Temperature |
Dimension |
Weight |
YKZ-04Ⅱ |
4 |
2L |
30±1r/min |
AC 220V |
Room temperature |
808*530* 700mm |
30kg |
YKZ-06Ⅱ |
6 |
2L |
30±1r/min |
AC 220V |
Room temperature |
978*530* 700mm |
35kg |
YKZ-08Ⅱ |
8 |
2L |
30±1r/min |
AC 220V |
Room temperature |
1050*530*700mm |
40kg |
YKZ-10Ⅱ |
10 |
2L |
30±1r/min |
AC 220V |
Room temperature |
1148*530*700mm |
45kg |
YKZ-12Ⅱ |
12 |
2L |
30±1r/min |
AC 220V |
Room temperature |
1400*530*700mm |
50kg |
Main Parameter
1. Applied to standard - sulphuric acid method >(HJ/299-2007)& Solid waste extraction toxicity identification method > (HJ/300-2007)
2. Applied to inorganic pollutant and volatile/half-volatile organic pollutant extraction toxicity identification.
3. Platform Shaker can work continuously for 18H above.
4. Rotation Rate: 30±1r/min, adapt to long term heavy load rotation.
5. The device contacting surface with samples is made of inert material which won’t extract or absorb the sample composition.
6. Platform Shaker can display 2L capacity glass bottle, PE bottle, Teflon bottle & pollutant extraction container.
Detailed Images
Company Information
The Advantages of YLK:
1. With 8 years self research & manufacture experience;
2. National innovation fund supported;
3. Lab pretreatment machines stipulated by Chinese standard HJ637-2012, HJ/T300-2007, American EPA 1311.
4. Reasonable price for customer.
5. Warm service.
Profile of YLK
YLK is founded in 2006, specialized in researching & manufacturing varies laboratory pretreatment equipment. As one of Chinese National Innovation Fund Support Enterprise, we insist on self-innovation and have successfully broken up the foreign companies monopoly in China by inventing varies laboratory equipment, such as automatic rotation agitator, zero head space extractor and automatic digestion equipment.
During 10 years developing, we have successfully met varies requirements from customers and owned great reputation from Chinese Academy of Sciences, Tsinghua University, Guangdong Environmental Monitoring Center, Centre Testing International, Zijin Mining Group Company Limited, etc.
The members of YLK researching & technical support team are all with bachelor above degree & 5 years above working experience. And all the products are with independent intellectual property, including 2 patents and 45 utility models.
Our Customers
Our Services